-
1 аллюминизация (Aluminization consists in enriching with aluminum the metal of the part to be treated and is used for protecting hot metal parts , and in particular for improving resistance to corrosi
General subject: aluminization treatmentУниверсальный русско-английский словарь > аллюминизация (Aluminization consists in enriching with aluminum the metal of the part to be treated and is used for protecting hot metal parts , and in particular for improving resistance to corrosi
-
2 standard method for measurement of stain resistance of anodic coatings on aluminum
метод проверки качества анодирования алюминия (анодированная поверхность алюминиевых образцов после уплотнения окисной плёнки обрабатывается раствором HNO₃ и образец помещается на 5 мин в раствор, содержащий специальный краситель. Затем испытуемая поверхность образца промывается водой и протирается порошком пемзы. Если после этого на поверхности образцов появляется пятна, то качество анодирования низкое. Отсутствие пятен свидетельствует об удовлетворительном качестве уплотнения окисной плёнки)Англо-русский словарь промышленной и научной лексики > standard method for measurement of stain resistance of anodic coatings on aluminum
-
3 алюминиевая резистентность
Русско-английский словарь нормативно-технической терминологии > алюминиевая резистентность
-
4 аллюминизация
General subject: (Aluminization consists in enriching with aluminum the metal of the part to be treated and is used for protecting hot metal parts, and in particular for improving resistance to corrosi aluminization treatment -
5 высокопрочная сталь
1. high-tensile steel2. high-resistance steelРусско-английский новый политехнический словарь > высокопрочная сталь
-
6 длительный допустимый ток
(длительный) допустимый ток
Максимальное значение электрического тока, который может протекать длительно по проводнику, устройству или аппарату при определенных условиях без превышения определенного значения их температуры в установившемся режиме
[ ГОСТ Р МЭК 60050-826-2009]
Этот ток обозначают IZ
[ ГОСТ Р 50571. 1-2009 ( МЭК 60364-1: 2005)]EN
(continuous) current-carrying capacity
ampacity (US)
maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
[IEV number 826-11-13]
ampacity
The current in amperes that a conductor can carry continuously under the conditions of use without exceeding its temperature rating.
[National Electrical Cod]FR
courant (permanent) admissible, m
valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
[IEV number 826-11-13]Ampacity, the term is defined as the maximum amount of current a cable can carry before sustaining immediate or progressive deterioration. Also described as current rating or current-carrying capacity, is the RMS electric current which a device can continuously carry while remaining within its temperature rating. The ampacity of a cable depends on:
- its insulation temperature rating;
- conductor electrical properties for current;
- frequency, in the case of alternating currents;
- ability to dissipate heat, which depends on cable geometry and its surroundings;
- ambient temperature.
Electric wires have some resistance, and electric current flowing through them causes voltage drop and power dissipation, which heats the cable. Copper or aluminum can conduct a large amount of current before melting, but long before the conductors melt, their insulation would be damaged by the heat.
The ampacity for a power cable is thus based on physical and electrical properties of the material & construction of the conductor and of its insulation, ambient temperature, and environmental conditions adjacent to the cable. Having a large overall surface area may dissipate heat well if the environment can absorb the heat.
In a long run of cable, different conditions govern, and installation regulations normally specify that the most severe condition along the run governs the cable's rating. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. Derating is necessary for multiple circuits in close proximity. When multiple cables are near, each contributes heat to the others and diminishes the amount of cooling air that can flow past the individual cables. The overall ampacity of the insulated conductors in a bundle of more than 3 must be derated, whether in a raceway or cable. Usually the de-rating factor is tabulated in a nation's wiring regulations.
Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75 and 90 degrees Celsius, often with an ambient air temperature of 30°C. In the U.S., 105°C is allowed with ambient of 40°C, for larger power cables, especially those operating at more than 2 kV. Likewise, specific insulations are rated 150, 200 or 250°C.
The allowed current in cables generally needs to be decreased (derated) when the cable is covered with fireproofing material.
For example, the United States National Electric Code, Table 310-16, specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30°C, the conductor surface temperature allowed to be 75°C. A single insulated conductor in air has 70 A rating.
Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. The acceptable magnitude and duration of overcurrent is a more complex topic than ampacity.
When designing an electrical system, one will normally need to know the current rating for the following:- Wires
- Printed Circuit Board traces, where included
- Fuses
- Circuit breakers
- All or nearly all components used
Some devices are limited by power rating, and when this power rating occurs below their current limit, it is not necessary to know the current limit to design a system. A common example of this is lightbulb holders.
[http://en.wikipedia.org/wiki/Ampacity]
Тематики
- электротехника, основные понятия
Синонимы
EN
DE
- Dauerstrombelastbarkeit, f
- Strombelastbarkeit, f
FR
- courant admissible, m
- courant permanent admissible, m
Русско-английский словарь нормативно-технической терминологии > длительный допустимый ток
См. также в других словарях:
Aluminum wire — is a type of wiring used in houses and power grids. History Usage within utilities Since the early 1900s, utility companies have been using aluminum wire for transmission of electricity within their power grids. It has advantages over the older… … Wikipedia
Resistance wire — is electrical wire used for its resistance. It is routinely used at high temperatures, so normally also has high melting point.Resistance wire is usually used for high power resistors and heating elements, which produce heat used in electric… … Wikipedia
Aluminum — A*lu mi*num ([.a]*l[=u]*m[i^]*n[u^]m), n. The metallic element forming the base of alumina. This metal is white, but with a bluish tinge, and is remarkable for its resistance to oxidation, and for its lightness, having a specific gravity of about … The Collaborative International Dictionary of English
aluminum processing — Introduction preparation of the ore for use in various products. Aluminum, or aluminium (Al), is a silvery white metal with a melting point of 660° C (1,220° F) and a density of 2.7 grams per cubic centimetre. The most abundant… … Universalium
aluminum bronze — any of several alloys containing a high percentage of copper with from 5 to 11 percent aluminum and varying amounts of iron, nickel, manganese, and other elements. Also called albronze. [1870 80] * * * ▪ alloy any of a group of strong,… … Universalium
aluminum — A white silvery metal of very light weight; atomic no. 13, atomic wt. 26.981539. Many salts and compounds are used in medicine and dentistry. [L. alumen, alum] a. acetate used as a disinfectant by embalmers; proposed as … Medical dictionary
aluminum bronze — noun an alloy of copper and aluminum with high tensile strength and resistance to corrosion • Syn: ↑aluminium bronze • Hypernyms: ↑copper base alloy … Useful english dictionary
aluminum — noun Usage: often attributive Etymology: New Latin, from alumina Date: 1812 a bluish silver white malleable ductile light trivalent metallic element that has good electrical and thermal conductivity, high reflectivity, and r … New Collegiate Dictionary
1974 aluminum cent — Infobox Coin Country = United States Denomination = Cent Value = 0.01 Unit = U.S. dollars Mass troy oz = 0.030 Mass = 0.937 Diameter inch = 0.750 Diameter = 19.05 Thickness inch = 0.061 Thickness = 1.55 Edge = Plain/Smooth Composition = 96%… … Wikipedia
Copper-clad aluminum wire — Copper clad aluminum wire, commonly abbreviated as CCAW or CCA, is a conductor composed of an inner aluminum core and outer copper cladding. Uses The primary applications involve of this conductor revolve around weight reduction requirements.… … Wikipedia
Electric resistance welding — (ERW) refers to a group of welding processes such as spot and seam welding that produce coalescence of faying surfaces where heat to form the weld is generated by the electical reistance of material vs the time and the force used to hold the… … Wikipedia